NG5N 20.5x7.2x15.3 Features Small size, light weight. Switching capacity up to 5A. Low coil power consumption 0.2W. Suitable for household electrical appliance, automation system, electronic equipment, instrument, meter, telecommunication facilities and remote control facilities. Ordering Information NG5N A DC12V 1 2 3 1 Part numberNG5N 2 Contact ArrangementA:1A 3 Coil rated Voltage(V)DC:3,5,6,9,12,18,24 Contact Data Contact Arrangement Contact Material Contact Rating (resistive) Max. Switching Power Max. Switching Voltage Contact Resistance or Voltage drop Operation Electrical life Mechanical 1A SPSTNO Silver Alloy 5A/30VDC,250VAC 150W 1250VA 30VDC 250VAC 100m 105 107 min Switching load:10mA/5V Max. Switching Current:5A Item 3.12 of IEC255-7 Item 3.30 of IEC255-7 Item 3.31 of IEC255-7 CAUTION: Relays previously tested or used above 10mA resistive at 6VDC maximum or peak AC open circuit are not recommended for subsequent use in low level applications. Coil Parameter Coil voltage VDC Coil resistance 10% Max. 3.9 6.5 7.8 11.7 15.6 23.4 31.2 45 125 180 405 720 1620 2880 Pickup voltage VDC(max) (75%of rated voltage ) 2.25 3.75 4.50 6.75 9.00 13.5 18.0 release voltage VDC(min) (10% of rated voltage) 0.3 0.5 0.6 0.9 1.2 1.8 2.4 0.2 10 4 Coil power consumption W Operate Time ms Release Time ms Dash Numbers Rated 003-200 005-200 006-200 009-200 012-200 018-200 024-200 3 5 6 9 12 18 24 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release voltage are for test purposes only and are not to be used as design criteria. 41 www.dblectro.com NG5N Operation condition Insulation Resistance Dielectric Strength Between contacts Between contact and coil Shock resistance Vibration resistance Terminals strength Solderability Ambient Temperature Relative Humidity Mass 1000M min (at 500VDC) Item 7 of IEC255-5 Item 6 of IEC255-5 Item 6 and 8 of IEC255-5 IEC68-2-27 Test Ea IEC68-2-6 Test Fc IEC68-2-21 Test Ua1 IEC68-2-20 Test Ta method 1 IEC68-2-3Test Ca 50Hz 750V 50Hz 4000V surge voltage:7kV Functional:100m/s2 11ms Survival:1000m/s2 6ms 10~50Hz Functional & Survival double amplitude 1.5mm 5N 235x2 3x0.5s -30~70 20%~85% (at 40) 4g Qualification inspection: Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24. Dimensions (Unit: mm) mm 0.27 0.52 0.8 1.05 1.1 1.2 3.4 4.7 7 7.2 11.5 15.3 20.5 >acCa Mounting (Bottom views) Dimensions 0.011 0.020 0.031 0.041 0.043 0.047 0.134 0.185 0.275 0.283 0.453 0.602 0.807 Wiring diagram (Bottom views) NOTES 1).Dimensions are in millimeter. 2).Inch equivalents are given for general information only. www.dblectro.com |
Price & Availability of NG5NADC3V |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |